100 Ltr / Hr250 Ltr / Hr500 Ltr / Hr1000 Ltr / Hr

Features:

Compact design
Procon pump
SS Membrane housing
Membrane 25X40
Separate sand/carbon or dual media filter
Bag filter in 4″X20″ housing or spun in 2″X20″ housing
SV for auto flushing
Anti scalant dosing
SS 304 skid/ms powder coated skid
Back wash- manual & automatic both options available
Rotameter for flow indication
Pressure gauge for pressure indication
LPS, HPS, floty for raw water tank & treated water tank
100% automatic LCD pannel

Membrane 25X40 Membrane
High Pressure Pump Procom 400 LPH Pump
Raw Water Pump 400 LPH Pump
Dosing Pump 6 Ltr/Hr Dosing Pump
Duel Media Filter FRP 8X44, MPV 1/2″ half vessel filled with sand and half with carbon
Cartridge Filter Blue Housing 20″X2″ with wound or spun cartridge ro remove dust & particulars
Rota Meter 2 Rota meteres of 0-500 LPH eachTo show pure water flow and reject water flow
Pressure Gauge 2 Pressure Gauge of 0-20 Kg/cm2To show pressure of high pressure pump at inlet of membrane
LPS One LPSTo turn off the system if incoming water pressure is low
HPS One HPSTo turn off the system if pressure increases in the system
Skid SS 304/Ms powder coated
UV UV required if you want to adjust the TDS of water.To kill the bacteria for double protection.
UF Filter UF is used to mix the raw water in pure water to adjust the TDS.
Pressure Tube FRP 250 PSI or SS304
Floty One floty for raw water tank, one floty for pure water tank. It will turn off system when raw water tank in empty or pure water tank is full.
Plumbing U-PVC
Control Panel LCD display control panel which will be fully automatic. If raw water tank is empty RO will be turn off, if pure water tank is full RO will be turn off, if incoming water pressure is low RO will be turned off, if water pressure increases above some level RO wiil be turned off. Online TDS/conductivity of pure water can be checked and control.
Raw Water Required 400 LPH
Pure Water Flow 100 LPH
Reject Water Flow 300 LPH
TDS of Raw Water <1500 PPM
TDS of Pure Water 40 to 70 PPM
PH of Raw Water 7 to 7.5
PH of Pure Warer 6 to 6.5

Aqua phoenix Industriall RO 250 lil per hour

Features

Compact design
Procon pump
SS Membrane housing
Membrane 25X40
Separate sand/carbon or dual media filter
Bag filter in 4″X20″ housing or spun in 2″X20″ housing
SV for auto flushing
Anti scalant dosing
SS 304 skid/ms powder coated skid
Back wash- manual & automatic both options available
Rotameter for flow indication
Pressure gauge for pressure indication
LPS, HPS, floty for raw water tank & treated water tank
100% automatic LCD pannel

Membrane 40X40 Membrane
High Pressure Pump CDL 2.9 LPH Pump
Raw Water Pump 750 Ltr Flow Pump
Dosing Pump 6 Ltr/Hr Dosing Pump
Sand Filter FRP 8X44, MPV 1/2″, Simple crystal sandIf turbidity is more, special sand with extra cost
Carbon Filter FRP 8X44, MPV 1/2″, Carbon with 600 ID
Bag Filter Jumbo blue housing 4″X20″ with bag filter assemblyTo remove dust & particals
Cartridge Filter Jumbo blue housing 4″X20″ with wound or spun cartridgeTo remove dust & particals
Rota Meter 2 Rota meteres of 0-1000 LPH eachTo show pure water flow and reject water flow
Pressure Gauge 2 Pressure Gauge of 0-20 Kg/cm2 eachTo show pressure of high pressure pump
LPS One LPSTo turn off the system if incoming water pressure is low
HPS One HPSTo turn off the system if pressure increases in the RO
Skid SS 304/Ms powder coated
UV UV required if you want to adjust the TDS of water.To kill the bacteria for double protection.
UF Filter UF is used to mix the raw water in pure water to adjust the TDS.
Pressure Tube FRP 250 PSI or SS304
Floty One floty for raw water tank, one floty for pure water tank.
Plumbing U-PVC
Control Panel LCD display control panel which will be fully automatic. If raw water tank is empty RO will be turn off, if pure water tank is full RO will be turn off, if incoming water pressure is low RO will be turned off, if water pressure increases above some level RO wiil be turned off. Online TDS/conductivity of pure water can be checked and control.
Raw Water Required 750 Ltr/Hr
Pure Water Flow 250 Ltr/Hr
Reject Water Flow 500 Ltr/Hr
TDS of Raw Water <1500 PPM
TDS of Pure Water 40 to 70 PPM
PH of Raw Water 7 to 7.6
PH of Pure Warer 6 to 6.5

 

 

Aqua phoenix Industriall RO 500 lil per hour

Features:

Compact design
Procon pump
SS Membrane housing
Membrane 25X40
Separate sand/carbon or dual media filter
Bag filter in 4″X20″ housing or spun in 2″X20″ housing
SV for auto flushing
Anti scalant dosing
SS 304 skid/ms powder coated skid
Back wash- manual & automatic both options available
Rotameter for flow indication
Pressure gauge for pressure indication
LPS, HPS, floty for raw water tank & treated water tank
100% automatic LCD pannel

Membrane 40X40 Membrane (2 Nos)
High Pressure Pump CDL 2.15 LPH Pump
Raw Water Pump 1500 Ltr Flow Pump
Dosing Pump 6 Ltr/Hr Dosing Pump
Sand Filter FRP 8X44, MPV 1/2″, Simple crystal sandIf turbidity is more, special sand with extra cost
Carbon Filter FRP 8X44, MPV 1/2″, Carbon with 600 ID
Bag Filter Jumbo blue housing 4″X20″ with bag filter assembly
Cartridge Filter Jumbo blue housing 4″X20″ with wound or spun cartridge
Rota Meter 2 Rota meteres of 0-1000 LPH eachTo show pure water flow and reject water flow
Pressure Gauge 2 Pressure Gauge of 0-20 Kg/cm2 eachTo show pressure of high pressure pump
LPS One LPSTo turn off the system if incoming water pressure is low
HPS One HPSTo turn off the system if pressure increases in the RO
Skid SS 304/Ms powder coated
UV UV required if you want to adjust the TDS of water.To kill the bacteria for double protection.
UF Filter UF is used to mix the raw water in pure water to adjust the TDS.
Pressure Tube FRP 250 PSI or SS304
Floty One floty for raw water tank, one floty for pure water tank.
Plumbing U-PVC
Control Panel LCD display control panel which will be fully automatic. If raw water tank is empty RO will be turn off, if pure water tank is full RO will be turn off, if incoming water pressure is low RO will be turned off, if water pressure increases above some level RO wiil be turned off. Online TDS/conductivity of pure water can be checked and control.
Raw Water Required 1000 Ltr/Hr
Pure Water Flow 500 Ltr/Hr
Reject Water Flow 500 Ltr/Hr
TDS of Raw Water <1500 PPM
TDS of Pure Water 40 to 70 PPM
PH of Raw Water 7 to 7.5
PH of Pure Warer 6 to 6.5

Aqua phoenix Industriall RO 1000 lil per hour

Features:

Compact design
Procon pump
SS Membrane housing
Membrane 25X40
Separate sand/carbon or dual media filter
Bag filter in 4″X20″ housing or spun in 2″X20″ housing
SV for auto flushing
Anti scalant dosing
SS 304 skid/ms powder coated skid
Back wash- manual & automatic both options available
Rotameter for flow indication
Pressure gauge for pressure indication
LPS, HPS, floty for raw water tank & treated water tank
100% automatic LCD pannel

Membrane 80X40 Membrane
High Pressure Pump CDL 2-18, I Phase or II Phase Pump
Raw Water Pump 2000 Ltr Flow Pump
Dosing Pump 6 Ltr/Hr Dosing Pump
Sand Filter FRP 10X54, MPV 1″, Simple crystal sandIf turbidity is more, special sand with extra cost
Carbon Filter FRP 10X54, MPV 1″, Carbon with 600 ID
Bag Filter Jumbo blue housing 4″X20″ with bag filter assembly
Cartridge Filter Jumbo blue housing 4″X20″ with wound or spun cartridge
Rota Meter 2 Rota meteres of 0-2400 LPH eachTo show pure water flow and reject water flow
Pressure Gauge 2 Pressure Gauge of 0-20 Kg/cm2 eachTo show pressure of high pressure pump before membrane and after membrane
LPS One LPSTo turn off the system if incoming water pressure is low
HPS One HPSTo turn off the system if pressure increases in the RO
Skid SS 304/Ms powder coated
UV UV required if you want to adjust the TDS of water.To kill the bacteria for double protection.
UF Filter UF is used to mix the raw water in pure water to adjust the TDS.
Pressure Tube FRP 250 PSI or SS304
Floty One floty for raw water tank, one floty for pure water tank.
Plumbing U-PVC
Control Panel LCD display control panel which will be fully automatic. If raw water tank is empty RO will be turn off, if pure water tank is full RO will be turn off, if incoming water pressure is low RO will be turned off, if water pressure increases above some level RO wiil be turned off. Online TDS/conductivity of pure water can be checked and control.
Raw Water Required 2000 LPH
Pure Water Flow 1000 LPH
Reject Water Flow 1000 LPH
TDS of Raw Water <1500 PPM
TDS of Pure Water 40 to 70 PPM
PH of Raw Water 7 to 7.5
PH of Pure Warer 6 to 6.5

 

 

Leave a Reply